How it works
1. Safety check: OptiMate 5 Select must be connected to a battery (retaining minimum 0.5V) to activate its output.
2. Desulphation and recovery: if the battery's resistance is abnormally high due to sulphation, a higher voltage is automatically applied to overcome this so as to recover very flat or neglected batteries until they are able to accept the normal charge program.
3. Bulk charge: a constant current of 3A (4A in 6V mode) efficiently brings the battery close to full charge.
4. Charge: Pulse absorption, cell equalisation (balancing) and charge verification: Charging is delivered in controlled pulses that automatically equalise cell voltages, until the current has reduced below 400mA which is indicative of a battery that has reached full charge.
5. Charge retention test: when the monitored parameters confirm that an optimal charge has been achieved, the first check for battery (and connected system) power leakage commences. Depending on the voltage retained during 30 minutes, an "OK" (green LED) or "not OK" (red LED test result is displayed. These 30-minute test periods repeat hourly until the OptiMate 5 Select is disconnected, so that the battery status indication is continually updated.
6. Charge maintenance: during alternate 30 minute periods, the battery is offered charge current (up to the maximum) it needs to sustain it against any small connected loads or power leakage and against natural self-discharge. OptiMate 5 Select can stay connected to the battery indefinitely and the battery will stay cool and safe. And optimally charged. Of course.
Technical Specifications
Recommended for: AGM / MF, STD, GEL & spiral cell batteries from 3Ah to 120Ah (12V); 3Ah to 160Ah (6V)
Programme control: 9 stages, fully automatic
Input current max: 0.90A @ 100-240V
Typical annual energy cost: Less than £1.00 per year (continuous maintenance)
Reverse drain current: Less than 0.5mA
Output current (bulk charge): 3A (12V); 4A (6V)
Automatic desulphation: Yes
Charge time limit (bulk): 72 hours
Maintain / test cycles: 30 min/30 min (alternating hourly)
Charge retention test: 2 possible results - ‘good’ & ‘bad’
Size: 190 x 75 x 56mm
Weight: 1000g
Enclosure classification: IP54
Mounting: Easy direct wall mounting
Input cable length: 2m
Output cable length: 2m
Included Accessories: O1 Weatherproof Eyelet Lead; O4 Clamps Lead for bench charging
Operation temperature range: -40°C / +50°C
Warranty: 3 years
Certification (230V model): TUV/GS conformity